Specialty Concepts, Inc.
Photovoltaic Charge Controller
The ASC photovoltaic battery charge controller is ideal for
1-4 solar panel systems.
This unit offers unsurpassed protection to your batteries from overcharging.
This rugged unit holds the record for high reliability since 1981. The standard ASC is UL recognized and is FM approved for hazardous locations.
The ASC is also CSA approved for Canadian markets.
FEATURES:
Charge Regulations
- 12 volt units: 4,8,12, 16 & 20 amps
- 24 volt units: 8 and 16 amps
- 6, 36 and 48 volt units available (contact factory for current ratings)
- Switching shunt, pulse charging
- Low switching frequency (no noise)
- No minimum operating voltage (can charge a dead battery)
- Remote temperature compensation (optional, not available on 6 volt)
Low Voltage Load Disconnect (LVD) (option)
- 10 amp LVD Relay
- Contacts for generator start or alarm
Design Features
Completely encapsulated for environmental protection (suitable for outdoor mounting)
- 100% solid state charge control
- Reverse leakage protection -blocking diode
- Lightning protection
- Input noise suppression
- Low power consumption
- Simple (low component count) with rugged circuitry
- 12 AWG terminal block (10 AWG stranded OK)
Monitoring and Mounting
- Charging light
- LVD activated light (with LVD)
OPERATION
Switching Shunt Regulation -
The ASC will allow maximum array current to flow into the battery through a blocking diode, lighting the "CHARGING" light (LED), until the battery voltage reaches the charge termination set-point. At this point, a shunt transistor will turn on, shorting out the solar array, turning off the "CHARGING" LED and halting any further battery charging. When the battery voltage drops to the charge resumption set-point, the shunt transistor will turn off and charging will resume. The result is that when battery capacity is low, charging will be
continuous. As the battery charges up, current will pass into the battery for shorter and shorter periods, until at full charge, it will pulse current into the battery to achieve and maintain full charge.
For Larger Arrays -
The ASC can be wired in parallel to sub-arrays. This method provides the added reliability of independent, redundant charge controls and allows for sequential charging.
OPTIONS
A - Temperature Compensation:
Temperature compensation is generally recommended for sealed batteries or where batteries are expected to experience temperature variations of more than + 10° from 25°C during periods of charging. A small temperature sensor on a 10 foot lead monitors battery temperature and adjusts the charging thresholds according to battery temperature. The rate of compensation is -5mv/°C per battery cell from 25°C.
E - Low Voltage Disconnect (LVD) /Generator Start:
The ASC can be provided with an auxiliary relay. This relay can be used to protect the battery from low-voltage damage by disconnecting loads or by signaling a standby generator to start or stop battery charging. The relay is rated for 10 amps and provides the common, the normally open and the normally closed voltage free contacts. The relay consumes 30 ma when activated and is activated at 1.92 + .03 volts/cell and deactivated at 2.17 + .03 volts/cell. A separate terminal block is provided for connection.
F - Adjustability:
The ASC may be ordered with the adjustment pot available to change the charging set-points if required. Load disconnect set-points are also adjustable for units with E-option (LVD / Gen. start).
|