Trouble Shooting Table
Symptoms/Codes |
Probable Causes/Conditions |
Investigative/Corrective Actions |
No Hot Water & No Power to the heater
Possible codes are:
None
(LED not on) |
Breaker(s) at main panel or sub-panel
No Voltage
Incorrect wiring |
Check / reset breakers — most models have multiple power circuits (refer to heater specifications). Verify that the breakers marked for the heater are actually the breakers serving the heater.
Check for power at the lugs. Refer to the Component Testing Table for proper voltage measurements at the lugs.
If breakers are on and there is no power at the lugs, It may be possible the electrical wiring is out-of phase to one or more of the incoming power circuits. Turn off all power to the heater and re-wire the circuits until all circuits are measuring 208 to 240 volts across each pair of lugs, L1 & L2. It is recommended that this be done by a licensed contractor. |
No Hot Water & Power verified at all incoming circuit lugs
Possible codes are:
None, (LED flashing all green) or the following red flashing codes:
122 or
123 or
126 or
127 or
127 & 142 or
142 |
Check Self Diagnostic Codes, each listed in the Diagnostic Troubleshooting Code section
Heater undersized for application |
Check the LED on the control board for self diagnostic codes.
If LED is flashing red code(s), refer to how to read the code, refer to Diagnostic Codes for possible causes and corrective action.
If LED is solid red and there are two LED’s, the control board is an older version analog control, made prior to May, 1999. The diagnostic codes do not apply to the analog control. Call Microtherm, Inc. for troubleshooting procedure.
No code: Check water demands, including flow rate and inlet water temperature. Also, check the service voltage. If the service is 208 volts AC, and the heating elements are rated for 240 volts AC, the power rating and the flow rate capability of the heater will be decreased. Refer to the heater’s ratings and flow rate specifications. Note: a 127 code may occur during periods of flow that exceed the heater capacity.
If possible, throttle back the flow at the faucet or the shut-off valve. Seisco heaters should be sized for maximum flow rate(s) and the highest temperature rise(which usually occurs in the winter months). |
Symptoms/Codes |
Probable Causes/Conditions |
Investigative/Corrective Actions |
No Hot Water & Power verified at all incoming circuit lugs
CONTINUED......
122 or
123 or
126 or
127 or
127 & 142 or
142 |
Tripped High Limit Switch
No water or low water level in heater
Water Leak
Power outage, voltage spike or surge
Control Data Reading Error |
122 code: Check for a tripped high temp. limit switch. If tripped, turn off all power to the heater. Reset the switch by pushing in the button on the switch itself. Check the switch and brown wires for continuity. If the switch is open, see High Limit Switch Replacement in the Removal and Repair section. Replace the switch. If the switch is not open, check further for possible temperature sensor or temperature sensor wire problems. After adjusting or replacing the temperature sensor, perform the Matching Procedure.
123 code: Check that the heater is filled with water and that there is no air trapped inside. Purge the hot water lines if necessary. Check operation of back flow preventer (or check-valve). If the heater is filled and there are no leaks, ground both level detect spades on the board. The 123 code should go away. If so, do not leave the level detect grounded out as it will eliminate this very important safety feature.
126 code: Check for water leaking at the connections to the inlet and outlet fittings, the level detector screws, the limit switches, the elements and the temperature sensors. With all power off to the heater, tighten or replace according to the specifications found in the Removal and Repair section of this manual. Refer to Diagnostic Codes for more corrective steps.
127 & 142 codes: The heater needs to be reset. Turn off all breakers to the heater for approx. 30 seconds. Turn on breakers and check LED status. The LED should flash all green and heater should produce hot water. If both codes remain, refer to temperature sensor and heating element testing. Perform the Matching Procedure.
142 code: The heater needs to be reset. Turn off all breakers to the heater for approx. 30 seconds. Turn on breakers and check LED status. The LED should flash all green and heater should produce hot water. If the 142 code remains, try re-stetting the breakers again. If 142 code persists, refer to temperature sensor testing in the Component Testing Table. If temperature sensors and wires are good, perform Matching Procedure. If the 142 code does not clear, see control board replacement in Removal and Repair section. |
Symptoms/Codes |
Probable Causes/Conditions |
Investigative/Corrective Actions |
Water Not Hot Enough or Fluctuating Temperatures
CONTINUED....
Possible codes are:
None or
111 & 118 or 117
112 & 118 or 117
113 & 118 or 117
114 & 118 or 117
115 & 118 or 117
127 or
127 & 142 |
Breaker(s) at main panel or sub-panel
Incorrect wiring
Loose connection
Temperature adjusted too low
Heater undersized for application |
127 code: Check / reset breakers — most models have multiple power circuits (refer to heater specifications). Verify that the breakers marked for the heater are actually the breakers serving the heater.
127 code: With breakers on, check for power at the lugs. Refer to the Component Testing Table for proper voltage measurements at the lugs.
It is possible the electrical wiring is out-of phase to one or more of the incoming power circuits. Turn off all power to the heater and re-wire the circuits until all circuits are measuring 208 to 240 volts across each pair of lugs, L1 & L2. It is recommended that this be done by a licensed contractor.
127 code: Turn off all breakers and check lugs and heating elements for loose or disconnected wires. If necessary, tighten or reconnect wires and turn on the breakers. Test water.
No Code: Check the thermostat setting. If adjustable knob is turned all the way to the left, temperature output may be below 95 degrees F. Turn the knob to the right to increase temperature.
No code: Check water demands, including flow rate and inlet water temperature. Also, check the service voltage. If the service is 208 volts AC, and the heating elements are rated for 240 volts AC, the power rating and the flow rate capability of the heater will be decreased. Refer to the heater ratings and flow rate specifications. Note: a 127 code may occur during periods of flow that exceed the heater capacity. |
Back to Top
Symptoms/Codes |
Probable Causes/Conditions |
Investigative/Corrective Actions |
Water Not Hot Enough or Fluctuating Temperatures
CONTINUED..... |
Temperature sensor problem or bad temperature sensor wire or wire connection
Bad heating element |
127 & 142 codes:
The following codes are also used by the control to identify the problem temperature sensor, (refer to the Diagnostic Codes for more detail):
111, 112, 113, 114, 115, 117 & 118
Turn off all breakers to heater. Allow heater to cool down by running cold water through the heater for approx. 5 minutes. Measure the ohms on each temperature sensor and wire by placing the ohm-meter probes on the control board where the red and green wires are connected to the spade terminals, (Refer to the Component Testing Table for expected values).
If there is a low reading (20 ohms or less), further test the suspected wires and temperature sensor individually to determine which is at fault.
Replace the wire if there is no continuity. If the temperature sensor has a low ohm reading (20 ohms or less), pull off the red cap to the temperature sensor exposing the threaded stem. While holding the base of the temperature sensor with a small wrench, so it doesn’t move, turn the stem _ turn with a pair of pliers. Check the ohm reading again. If it is still low, turn the stem another _ turn until a good reading is achieved.
If the ohm reading doesn’t change, see Temperature sensor Replacement in the Removal and Repair section. Perform the Matching Procedure after adjusting or replacing the temperature sensor.
127 code: Turn off all power to the heater and ohm the heating elements. Refer to the Component Testing Table for expected ohm readings. If a heating element is bad, there will be no continuity or an infinite ohm reading (the meter may display "no reading" or "open"). See the Removal and Repair section for heating element replacement. |
Symptoms/Codes |
Probable Causes/Conditions |
Investigative/Corrective Actions |
Water Runs Hot and Then Cold
Possible codes are:
None or
124 or
127 & 142
|
Water lines reversed
High temperature shut-down |
127 & 142 codes: Turn on the hot water at a faucet. At the heater, if the outlet pipe (on the left) feels cold and the inlet pipe (on the right) feels hot or warm, then the water lines are reversed. Reconnect the water lines so that the hot water line is connected to the outlet fitting and the cold water line is connected to the inlet fitting. This may need to be done by a licensed contractor.
124 code: This code is triggered when the temperature of the water is more than 10 degrees higher than the set-point at any of the temperature sensors. Typically, this occurs in two chamber heaters when the hot water is shut off abruptly and latent heat builds up in the chamber. Also, it may occur in a four chamber heater used in circulating systems and booster applications, because additional heated water is entering the chamber from the inlet side. This increases the chances of latent heat build-up when the water is abruptly shut-off. The 124 code should clear after the hot water clears the temperature sensors or the heater cools down. If the 124 doesn’t clear or the heater does not turn on and the 124 code persists, call Microtherm for further assistance. |
LED Stays on Solid Red |
Analog control board
Digital control board |
If the LED is solid red and there are two LED’s, the control board is an older version analog control, made prior to May, 1999. The diagnostic codes do not apply to the analog control. Call Microtherm, Inc. for troubleshooting procedure.
Turn off all power to the heater and wait 30 seconds. Then turn on the power. If the LED remains solid red and doesn’t flash, then see Replacing the Board in the Removal and Repair section. Replace the control board and perform the Matching Procedure. |
LED Does Not Come On |
Breaker(s) at main panel or sub-panel
No Voltage |
Check / reset breakers — most models have multiple power circuits (refer to heater specifications). Verify that the breakers marked for the heater are actually the breakers serving the heater.
Check for power at the lugs. Refer to the Component Testing Table for proper voltage measurements at the lugs. |
Symptoms/Codes |
Probable Causes/Conditions |
Investigative/Corrective Actions |
LED Does Not Come On
CONTINUED..... |
Incorrect wiring
Bad LED
Bad control board |
If breakers are on and there is no power at the lugs, it may be possible the electrical wiring is out-of phase to one or more of the incoming power circuits. Turn off all power to the heater and re-wire the circuits until all circuits are measuring 208 to 240 volts across each pair of lugs, L1 & L2. It is recommended that this be done by a licensed contractor.
With all the power on to the heater, and the water running full flow, take amp readings on each red or black heating element wire (refer to the Component Testing Table for expected amp readings). If there are amps measured through all the individual heating element
wires, then the LED may be bad. Make sure the light is not being obscured by sun glare or a bright room. Also, activate the audible by removing one of the brown wires from the board and pressing the blue button. If the audible produces the 122 code, then the board is functioning properly. However, if the amp readings through the heating element wires are all zero, then see replacing the control board in the Removal and Repair section. Replace the control board and perform the Matching Procedure.
Turn off all power to the heater and wait 30 seconds, then turn on the power. If the LED does not come on, see Replacing the Control Board in the Removal and Repair section. Replace the control board and perform the Matching Procedure. |
Back to Top |
|
|
|
|
|
• Personal Assistance
• Toll Free Support
• Product Selection
. . . . . . . . . . . . . . . .
CASH REBATES!
Federal, State &
Local Utility Cash
Rebates for Solar
& Energy Efficient
Technologies.
» Cash Rebates
|
|
• Technical Assistance;
Toll Free support for
Do-It-Yourself Kits,
system configuration,
installation info, and
rebate consultations
|
|
|
|